PTT評價

[問題] 新買的創見230s 2TB這樣正常嗎?

看板Storage_Zone標題[問題] 新買的創見230s 2TB這樣正常嗎?作者
Rokugo
(麓鄉)
時間推噓 5 推:5 噓:0 →:6

最近創見230s 2TB特價後比MX500便宜,
於是昨晚就當了勇者買了,結果今天到貨後用SMI FLASH ID去看
非常的奇怪:

Model: TS2TSSD230S
Fw : 22Z3V4EI
Size : 1953514 MB [2048.4 GB]
From smart : [SMI2259TLC2R] [22Z3V4EI]
Controller : SM2259AB
Bank00: 0x32,0x32,0x35,0x39,0x41,0x42,0x0,0x0 -
Pure Spare Blocks : 0
Running Spare Blocks: 0

 因為我是想要看Dram有沒有縮水
結果發現連顆粒是啥都看不到了,大多都是顯示上述畫面
 除非是我剛跑完Chrystal Diskmark這種,再去執行SMI FLASH ID
才有辦法看部分Bank有顯示顆粒
而且是混合各種牌子的顆粒,甚至同一Bank顯示的顆粒還不一樣
像是:

Model: TS2TSSD230S
Fw : 22Z3V4EI
Size : 1953514 MB [2048.4 GB]
From smart : [SMI2259TLC2R] [22Z3V4EI]
Controller : SM2259AB
Bank00: 0x32,0x32,0x35,0x39,0x41,0x42,0x2f,0x58 -
Bank01: 0x6d,0x97,0x56,0x7e,0x60,0xc6,0xc,0xbb -
Bank02: 0xb8,0x4,0xe2,0x5f,0x27,0x13,0x47,0x78 -
Bank03: 0x5e,0xd3,0xf4,0x9e,0xdb,0xff,0x25,0xb0 -
Bank04: 0x7,0x68,0xa,0x6d,0xce,0x4,0xe7,0x3d - Renesas TLC
Bank05: 0x27,0xda,0xbf,0x28,0x2,0x1e,0xba,0xe2 -
Bank06: 0x81,0x88,0xdc,0x42,0xa8,0x4d,0x8d,0x0 -
Bank07: 0x34,0x2,0xaa,0x60,0xb,0xee,0xf4,0x36 -
Bank08: 0xe2,0x9a,0x43,0xfb,0xb4,0xf5,0x10,0xd -
Bank09: 0xeb,0x60,0xe6,0xdb,0x18,0x57,0xb0,0x40 -
Bank10: 0x83,0x2f,0xd0,0xd3,0xfe,0x67,0x5d,0x6d -
Bank11: 0xc4,0x74,0xf4,0xb,0x2e,0x52,0x8d,0x8f -
Bank12: 0x4,0xdd,0xe3,0x45,0xa1,0xb8,0x67,0x35 - Fujitsu SLC
Bank13: 0x2e,0xb4,0x90,0x78,0x2d,0xb9,0xf9,0xa -
Bank14: 0x82,0x97,0x52,0x73,0xe6,0xc2,0x26,0x25 -
Bank15: 0xf7,0x63,0xf9,0x9f,0xb9,0xbe,0x90,0x7d -
Bank16: 0xef,0xd6,0x90,0x92,0x3b,0x34,0xae,0xb - Winbond SLC
Bank17: 0xb0,0x19,0x96,0xaa,0x63,0x8,0x26,0x96 -
Bank18: 0xc3,0xe1,0xbb,0xff,0x2,0x75,0xeb,0x3f -
Bank19: 0x15,0xc8,0xb5,0xeb,0x5c,0xb,0x3d,0xfd -
Bank20: 0x72,0x83,0x9e,0x2b,0xbb,0xf,0x17,0xa5 -
Bank21: 0x16,0xff,0x77,0xa5,0x50,0x64,0x4b,0xc7 -
Bank22: 0x16,0x38,0xfa,0xd8,0xd5,0xff,0xc7,0x12 -
Bank23: 0x8a,0xf7,0x85,0x4f,0xfb,0x1f,0x95,0x61 -
Bank24: 0xfb,0xd5,0xe3,0x9e,0x59,0x9,0x84,0x6e -
Bank25: 0x40,0xca,0xdd,0xf6,0x9c,0x7e,0x73,0xf5 -
Bank26: 0xf4,0xaf,0x92,0xf4,0x26,0xf4,0x7b,0xcc -
Bank27: 0x4c,0x78,0x39,0x55,0x89,0x78,0xcd,0xac -
Bank28: 0x37,0xfb,0x10,0x5e,0x35,0x4d,0x38,0x27 -
Bank29: 0xb2,0x63,0x40,0x64,0x6,0x5e,0xdf,0xd2 -
Bank30: 0x67,0x27,0x37,0xe5,0xf0,0x5d,0x27,0xe8 -
Bank31: 0x13,0x9f,0x4a,0xde,0xf6,0xaf,0x58,0x44 -
Pure Spare Blocks : 24014
Running Spare Blocks: 54354

或是

Model: TS2TSSD230S
Fw : 22Z3V4EI
Size : 1953514 MB [2048.4 GB]
From smart : [SMI2259TLC2R] [22Z3V4EI]
Controller : SM2259AB
Bank00: 0x32,0x32,0x35,0x39,0x41,0x42,0x0,0x0 -
Bank01: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank02: 0x2,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 -
Bank03: 0x1,0x0,0x0,0x4,0x23,0x0,0x0,0x0 - Spansion SLC
Bank04: 0x3,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 -
Bank05: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank06: 0x1,0x0,0x0,0x4,0x22,0x0,0x0,0x0 - Spansion SLC
Bank07: 0x1,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 - Spansion SLC
Bank08: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank09: 0x1,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 - Spansion SLC
Bank10: 0x1,0x0,0x0,0x4,0x22,0x0,0x0,0x0 - Spansion SLC
Bank11: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank12: 0x2,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 -
Bank13: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank14: 0x1,0x0,0x0,0x4,0x22,0x0,0x0,0x0 - Spansion SLC
Bank15: 0x1,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 - Spansion SLC
Bank16: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank17: 0x1,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 - Spansion SLC
Bank18: 0x1,0x0,0x0,0x4,0x22,0x0,0x0,0x0 - Spansion SLC
Bank19: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank20: 0x2,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 -
Bank21: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank22: 0x1,0x0,0x0,0x4,0x22,0x0,0x0,0x0 - Spansion SLC
Bank23: 0x1,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 - Spansion SLC
Bank24: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank25: 0x1,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 - Spansion SLC
Bank26: 0x1,0x0,0x0,0x4,0x22,0x0,0x0,0x0 - Spansion SLC
Bank27: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank28: 0x3,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 -
Bank29: 0x1,0x0,0x0,0x4,0x23,0x0,0x0,0x0 - Spansion SLC
Bank30: 0x2,0x0,0x0,0x3,0xf6,0x0,0x0,0x0 -
Bank31: 0x1,0x0,0x0,0x3,0xf7,0x0,0x0,0x0 - Spansion SLC
Pure Spare Blocks : 256
Running Spare Blocks: 3

還有


Model: TS2TSSD230S
Fw : 22Z3V4EI
Size : 1953514 MB [2048.4 GB]
From smart : [SMI2259TLC2R] [22Z3V4EI]
Controller : SM2259AB
Bank00: 0x32,0x32,0x35,0x39,0x41,0x42,0x0,0x2 -
Bank01: 0x26,0x0,0x0,0x2,0x28,0x0,0x0,0x2 -
Bank02: 0x38,0x0,0x0,0x2,0x47,0x0,0x0,0x2 -
Bank03: 0x49,0x0,0x0,0x2,0x3b,0x0,0x0,0x2 -
Bank04: 0x4e,0x0,0x0,0x2,0x49,0x0,0x0,0x2 -
Bank05: 0x42,0x0,0x0,0x2,0x4a,0x0,0x0,0x2 -
Bank06: 0x49,0x0,0x0,0x2,0x83,0x0,0x0,0x2 -
Bank07: 0x34,0x0,0x0,0x2,0x2f,0x0,0x0,0x2 -
Bank08: 0x32,0x0,0x0,0x2,0x40,0x0,0x0,0x2 -
Bank09: 0x2c,0x0,0x0,0x2,0x2b,0x0,0x0,0x2 - Micron SLC
Bank10: 0x27,0x0,0x0,0x2,0x89,0x0,0x0,0x2 -
Bank11: 0x1f,0x0,0x0,0x2,0x17,0x0,0x0,0x2 -
Bank12: 0x3e,0x0,0x0,0x2,0x2d,0x0,0x0,0x2 -
Bank13: 0x8c,0x0,0x0,0x2,0x30,0x0,0x0,0x2 -
Bank14: 0x8e,0x0,0x0,0x2,0x65,0x0,0x0,0x2 -
Bank15: 0xf,0x0,0x0,0x1,0xfe,0x0,0x0,0x2 -
Bank16: 0x10,0x0,0x0,0x2,0x16,0x0,0x0,0x2 -
Bank17: 0x36,0x0,0x0,0x2,0x0,0x0,0x0,0x2 -
Bank18: 0x2f,0x0,0x0,0x2,0x17,0x0,0x0,0x2 -
Bank19: 0x4b,0x0,0x0,0x2,0x34,0x0,0x0,0x2 -
Bank20: 0x40,0x0,0x0,0x2,0x9d,0x0,0x0,0x2 -
Bank21: 0xe2,0x0,0x0,0x2,0x13,0x0,0x0,0x2 -
Bank22: 0x7,0x0,0x0,0x2,0x81,0x0,0x0,0x2 - Renesas SLC
Bank23: 0x74,0x0,0x0,0x1,0xfe,0x0,0x0,0x2 -
Bank24: 0xf,0x0,0x0,0x2,0x7e,0x0,0x0,0x1 -
Bank25: 0xff,0x0,0x0,0x2,0xe,0x0,0x0,0x2 -
Bank26: 0x64,0x0,0x0,0x2,0x23,0x0,0x0,0x2 -
Bank27: 0x6f,0x0,0x0,0x2,0x71,0x0,0x0,0x1 -
Bank28: 0xff,0x0,0x0,0x2,0x0,0x0,0x0,0x2 -
Bank29: 0x2b,0x0,0x0,0x2,0x26,0x0,0x0,0x2 -
Bank30: 0x9,0x0,0x0,0x2,0x7a,0x0,0x0,0x2 -
Bank31: 0x2c,0x0,0x0,0x2,0x18,0x0,0x0,0x2 - Micron SLC
Pure Spare Blocks : 5888
Running Spare Blocks: 2

以及有QLC的:

Model: TS2TSSD230S
Fw : 22Z3V4EI
Size : 1953514 MB [2048.4 GB]
From smart : [SMI2259TLC2R] [22Z3V4EI]
Controller : SM2259AB
Bank00: 0x32,0x32,0x35,0x39,0x41,0x42,0x0,0x0 -
Bank01: 0x1,0x18,0xf9,0xa,0xca,0x0,0x0,0x0 - Spansion TLC
Bank02: 0x1,0x18,0xf9,0x92,0x35,0x0,0x0,0x0 - Spansion TLC
Bank03: 0x1,0x18,0xfa,0x67,0x1e,0x0,0x0,0x0 - Spansion TLC
Bank04: 0x1,0x18,0xfb,0x41,0x8c,0x0,0x0,0x0 - Spansion TLC
Bank05: 0x1,0x18,0xfc,0xac,0x25,0x0,0x0,0x0 - Spansion QLC
Bank06: 0x1,0x18,0xfd,0x4b,0x10,0x0,0x0,0x0 - Spansion QLC
Bank07: 0x1,0x18,0xfe,0x9d,0x38,0x0,0x0,0x0 - Spansion QLC
Bank08: 0x1,0x18,0xff,0x83,0xed,0x0,0x0,0x0 - Spansion QLC
Bank09: 0x1,0x19,0x0,0x5a,0xf0,0x0,0x0,0x0 - Spansion SLC
Bank10: 0x1,0x19,0x1,0x20,0x66,0x0,0x0,0x0 - Spansion SLC
Bank11: 0x1,0x19,0x1,0xac,0xa,0x0,0x0,0x0 - Spansion SLC
Bank12: 0x1,0x19,0x2,0x84,0x0,0x0,0x0,0x0 - Spansion SLC
Bank13: 0x1,0x19,0x3,0x5b,0x8b,0x0,0x0,0x0 - Spansion SLC
Bank14: 0x1,0x19,0x4,0x47,0x2e,0x0,0x0,0x0 - Spansion MLC
Bank15: 0x1,0x19,0x5,0x25,0xc9,0x0,0x0,0x0 - Spansion MLC
Bank16: 0x1,0x19,0x6,0x28,0xd3,0x0,0x0,0x0 - Spansion MLC
Bank17: 0x1,0x19,0x6,0xfe,0x10,0x0,0x0,0x0 - Spansion MLC
Bank18: 0x1,0x19,0x8,0x0,0xea,0x0,0x0,0x0 - Spansion TLC
Bank19: 0x1,0x19,0x8,0xeb,0x66,0x0,0x0,0x0 - Spansion TLC
Bank20: 0x1,0x19,0xa,0xe6,0x7b,0x0,0x0,0x0 - Spansion TLC
Bank21: 0x1,0x19,0xb,0x95,0x56,0x0,0x0,0x0 - Spansion TLC
Bank22: 0x1,0x19,0xc,0x86,0xb7,0x0,0x0,0x0 - Spansion QLC
Bank23: 0x1,0x19,0xd,0x8e,0x7e,0x0,0x0,0x0 - Spansion QLC
Bank24: 0x1,0x19,0xe,0x6a,0x7b,0x0,0x0,0x0 - Spansion QLC
Bank25: 0x1,0x19,0xf,0xb9,0x9c,0x0,0x0,0x0 - Spansion QLC
Bank26: 0x1,0x19,0x10,0x4b,0xf7,0x0,0x0,0x0 - Spansion SLC
Bank27: 0x1,0x19,0x11,0x16,0xcb,0x0,0x0,0x0 - Spansion SLC
Bank28: 0x1,0x19,0x12,0x9,0x7b,0x0,0x0,0x0 - Spansion SLC
Bank29: 0x1,0x19,0x13,0x8,0xb9,0x0,0x0,0x0 - Spansion SLC
Bank30: 0x1,0x19,0x14,0x57,0x92,0x0,0x0,0x0 - Spansion MLC
Bank31: 0x1,0x19,0x15,0xa,0x8d,0x0,0x0,0x0 - Spansion MLC
Pure Spare Blocks : 281
Running Spare Blocks: 13517


想請問各位,為何SMI FLASH ID會有這樣的情形?




--

※ PTT 留言評論
※ 發信站: 批踢踢實業坊(ptt.cc), 來自: 1.161.39.187 (臺灣)
PTT 網址

Cubelia 07/18 03:52偵測異常,特定情況flashid會抓不到

Cubelia 07/18 03:53得用其它電腦來試

Ahhhhaaaa 07/18 05:27BIOS的SATA mode先不要用IRST?

Ahhhhaaaa 07/18 05:27(改成AHCI)

sorrojvr 07/18 07:51另一台電腦試試

saimeitetsu 07/18 07:53沒在資料庫的顆粒?

ps0411 07/18 09:49SATA SSD 不是都應該用 X光機開箱確認有無 DRAM 嗎

ps0411 07/18 09:49

Rokugo 07/18 21:16我今天換別台電腦,線也換了,也是一樣情形...

ayasesayuki 07/19 15:11創見不是料都寫得很清楚嗎 應該不會亂換吧

spfy 07/19 22:42雖然難說 但創見SSD我還是相信的...可以信吧...